Call me back | My basket | Checkout | Add to email list

     You are here: Website » Knowledge base

« back to website

Specification / Accelerometers

Accelerometers - IMU06-tactical

Technical Specification Accelerometers
Parameter Conditions Min Typ Max Unit
ACCELEROMETERS Each Axis        
Dynamic Range   5     g
Output resolution RS232   1/256   g/LSB
Output resolution CAN   0.001   g/LSB
Sensitivity Temperature Coefficient -40C ≤ TA ≤ +85˚C, 1 σ   10   ppm/˚C
Misalignment Axis-to-axis   0.035   Degrees
  Axis-to-frame (package)   1.0   Degrees
Nonlinearity Best-fit straight line, 5 g   0.1   % of FS
Bias Repeatability -40C ≤ TA ≤ +85˚C, 1 σ   3   mg
In-Run Bias Stability 1 σ   32   μg
Velocity Random Walk 1 σ   0.023   m/sec √hr
Bias Temperature Coefficient -40C ≤ TA ≤ +85˚C, 1 σ   0.03   mg/˚C
Output Noise No filtering   1.25   mg rms
Noise Density f = 25Hz, no filtering   0.055   mg √Hz rms
3 dB Bandwidth     40   Hz
Sensor Resonant Frequency     5.5   kHz

NOTE 1
Bias repeatability describes the effect of a variety of conditions on the long term behaviour of the device. It is not a measure of the short term bias stability which is given the in-run bias stability.

Page last modified on May 15, 2019, at 02:37 PM