Analogue inputs 20-51

Channel Number20-51
Total Length4 bytes
ChannelData1Data2Checksum

Voltage [V]= (Data1 * 256 + Data2 ) / 1000

The range on the analogue channel is 0-65.535v. The resolution is 1mv and the units are v.