Call me back | My basket | Checkout | Add to email list

     You are here: Website » Knowledge base

« back to website

ECUType / MBE967SerialInterface

MBE 967 Serial interface

The MBE 967 serial – Race Technology interface connects between the ECU and either a data logger or a dashboard enabling monitoring of all the data channels.

The output of the ECU must be enabled for continuous operation on the serial port. Please refer to your ECU documentation for instructions on how to do this.

For the output of the MBE ECU to be decoded correctly, the 16 channel output from the ECU must be set up to send the following data, which will appear on the following channels.

The ECU should be set up with following configuration:

Bytes Channel Data Length
1-2 Engine Speed 16 bit
3-4 Throttle percentage 8 bit
5-6 Lambda Sensor Voltage 8 bit
7-8 Lambda 8 bit
9-10 Coolant Temperature 8 bit
11-12 Air Temperature 8 bit
13-14 Manifold Pressure 8 bit
15-16 Engine Oil Pressure 8 bit
17-18 Injection Time 16 bit
19-20 Ignition Angle 8 bit
21-22 Fuel Pressure 8 bit
23-24 Engine Oil Temp 8 bit
25-26 Baro pressure 8 bit
27-28 P14 8 bit
29-30 P15 8 bit
31-32 P16 8 bit


The data appears on the following channels:

ECU Channel Race Technology name Resolution
Engine Speed Engine RPM (RPM) 25rpm
Throttle percentage Aux 1 (Throttle Position) 0.1%
Lambda Sensor Voltage NOT USED    
Lambda misc 1 (Lambda 1) 0.01
Coolant Temperature temperature 8 (Water Temperature) 0.1oC
Air Temperature temperature 1 (Ambient Air Temperature) 0.1oC
Manifold Pressure pressure 5 (Boost Pressure) 1mBar
Engine Oil Pressure pressure 2 (Oil Pressure) 1mBar
Injection Time measured time 1 (Fuel Inj 1 PW on) 1ms
Ignition Angle angle 2 (Ignition Angle) 0.1o
Fuel Pressure pressure 3 (Fuel Pressure) 1mBar
Engine Oil Temp temperature 9 (Oil Temp) 0.1oC
Baro pressure pressure 1 (Ambient Air Pressure) 1mBar
Page last modified on September 09, 2011, at 09:29 AM