RT_CFG_Trigger_4: End trigger additional condition configuration
RT_CFG_Test: 159, 4 (0x9F0420 + unit ID) (0x7C4)
Bytes 0->3: Additional condition threshold
Byte 4: Additional condition type
Byte 5: Additional condition parameters
Byte 6: Units for additional condition threshold
Byte 7: Unused
Additional condition threshold:
Intel signed integer
scaling x1000
units dependent on trigger 4 units (byte 6)
Additional condition type:
0 => NULL
1 => SPEED
2 => HALT / PULLAWAY (acceleration-based)
3 => ACCEL_LONG
4 => ACCEL_LAT
5 => ANALOG
6 => HARDWARE TRIGGER
7 => COMMAND MESSAGE
8 => DISTANCE
9 => HALT / PULLAWAY (speed-based)
10 => MARKER
Additional condition parameters:
Bits 0->1: Hardware index (ADC number for analog input, trigger number for trigger input, both zero-based)
Bits 2->6: Reserved
Bit 7: Polarity
0 => Falling
1 => Rising
Units for additional condition threshold:
If Byte 4 = 1 or 2: Speed Units
0 => m/s
1 => kph
2 => mph
3 => knots
Remaining values unused
If Byte 4 = 3 or 4: Accel units
0 => g
1 => m/s/s
Remaining values unused
If Byte 4 = 8: Distance units
0 => m
1 => ft
Remaining values unused
If Byte 4 = any other value:
No units