Call me back | My basket | Checkout | Add to email list

     You are here: Website » Knowledge base

« back to website

ECUType / KMSECU

KMS MP25 ECU

This data protocol is valid for data speeds of 9600 baud or 115200 baud, which can be set within the KMS software.

Default baud rate after reset is 115200 bit/sec.

Byte Name Race Technology Name Resolution
1 Engine speed Engine RPM (RPM) 25 RPM
2 Battery Voltage misc 3 (Battery voltage) 0.01 V
3 Air to Fuel Ratio misc 1 (Lambda 1) 0.01 lambda
4 Water temp temperature 8 (Water temp) 0.1 oC
5 Air Temp temperature 1 (Ambient Air Temperature) 0.1 oC
6 Boost pressure pressure 5 (Boost pressure) 0.1 kPa
7 Oil pressure pressure 2 (Oil pressure) 0.1 kPa
8 Ignition angle angle 2 (Ignition angle) 0.1o
9 Inject pulse time measured time 1 (Fuel Inj 1 PW on) µs
Page last modified on July 11, 2012, at 07:25 AM