File Menu
|
|
New
You can open up a new file with this menu. If you have made any changes to the file that you are currently using, then you will be prompted to save them before opening up a new one.
|
|
Load Profile
Loads a Monitor Configuration file from disk. Files are saved onto the disk with the extension .mon. ( For Load options click here)
|
|
Save Profile
Saves the present configuration to disk. If you are saving the file for the first time, the system will prompt you to provide a name. If, for example, you provide the filename config_1 the file will be saved as config_1.mon on the disk. (The variables allocated to the controls will also be saved along with the file).
|
|
Save Profile As
Saves the file with a different file name.
|
|
Load Variable Information
Loads a saved variable information file from disk. A manually saved variable file will have the file type .VAR
|
|
Save Variable Information
Save the current variable information to disk. If you have set up the variables for a specific usage, and may wish to use the same set again at a later point, this allows you to save the information into hard copy.
|
|
Restore Default Variable Information
This option restores the monitor variable information file to its original state.
|
Play Mode
Once you have finished configuring the interface, source data should be added to the capture data that is coming from the logger. This should be done before performing a run operation. When in Run Mode, the controls will be immediately refreshed according to the incoming data. You will be unable to do any configurations to the system whilst in Play Mode.
Edit mode
The Edit mode is set as the default when you open up the monitor software. By using this mode you can add controls to the Design window, set the properties of the placed controls, resize and move them, customize controls, add variables to the inputs of the control, customise variables, add multiple tabs and Save and Load Monitor profile files (MON files).
Set Data Source
You can either set a serial connection or a data file as the data source for the variables.
|
|
Serial Connection
|
|
To read data, you should select a port and set the baud rate. If you choose to get data via a GSM modem, then you should specify the telephone number.
|
|
Read from file
|
|
If your choose to set a .run file as the data source, the filename should be typed in the given box., before pressing the set button.
|
Exit
This function is used to exit to the system. You can either press the "X" mark at the top right corner of the window or, alternatively, press 'Alt' and 'F4' at the same time.
Load Profile( Layout ) Options
- Clear current layout, and load the new one
Clears current layout (Clear and close all tabs) and loads the new layout.
- Save the current one, clear current layout and load the new one
Current layout (all the tabs and controls on it) is saved, then clears the current layout and loads the new one.
- Load the new one on-top of the current layout
New layout is placed on top of the current layout.
When loading one layout on top of other, their controls are added in the following manner:
Let us assume that current layout has two tabs with controls and new one has three tabs with controls. Then controls from new layout’s tab 1 and tab 2 are added on top of the current layouts tab 1 and tab 2 respectively. Third tab is created and added to the current layout. Finally current layout’s tab names are replaced by new layouts tab names.
Controls from the current layout may not visible after loading the new one, because they might be covered by the new ones. In such a case simply drag and drop the new controls to another place to see the previous ones.
- Abort, and do not load the new layout
This option cancels the load layout operation.